National Convention Center

Location:
North Wall Quay, Dublin
Cladding Scope:

Plant Room cladding and weathering to Air Handling Units (AHU’s)

Roofing Scope:

4,500 sqm Paralon Bitumen bonded felt membrane system

Safety Achievements:
No accidents or incidents
Quality Objectives:
Certified and tested system in advance of equipment placement
Schedule:
6 months

Deane Roofing & Cladding were engaged by John Sisk & Son to install a Paralon roofing system to this landmark building in Dublin. The National Convention Centre was a turnkey project for the main contractor and with that came the responsibility for design. As part of that design, the roof had to accommodate a future refurbishment without disruption to the plant and equipment located on the roofs.

The building had five primary levels of roofing with the main roof consisting of the interface with the distinguished cylindrical façade. The roof over the backstage, a lower level plant room roof, the stair cores and lift shaft roofs.

The interface with the glazed drum had to be designed as a movement joint with several systems interfacing at the one location. The drainage line of the glazing had to be catered for, as well as the transition from the level glazed termination cill and change in roof levels.

The need to accommodate future refurbishment meant the selection of products was critical for the success of the project. Their compatibility and warranty had to be accounted for. The design of upstands and flashings needed to be changeable and replaceable in the future whilst maintaining the weathering of the roof.

Much of the roofing in and around plant areas was carried out in confined spaces and in some locations with no future access. This put huge significance on the quality of the work and the need for quality control and sign off before the arrival of plant.

This project completed a successful 5-year period working alongside John Sisk & Sons, on this landmark Spencer Dock, North Wall Quay commercial and residential development.

Our Projects

Testimonials

I have worked and am currently working very closely with Deane Roofing and Cladding on a large high specification Biotechnology construction project. Their commitment to meet the very high expectations in quality, safety and schedule is second to none. They are very committed to reaching these expectations and surpassing them. They are very easy to work with on day to day construction issues and work diligently to ensure they deliver a top class project to all concerned.
Andrew McHugh
CSA Works Package Owner
Brennan Associates, Quantity Surveyors have worked on many projects with Deane Roofing and Cladding where they were specialist subcontractors for the Roofing and Cladding elements. Each project has been unique in its own way challenging the Design Team and Contractors alike. In these situations, we have found their team to be engaging, responsive, and technically proficient in resolving issues as they arose.

They have always maintained a high standard of workmanship, management, budget control and coordination with meticulous attention to detail being exerted throughout the projects. We would have no hesitation in recommending them for commercial roofing and cladding projects.
John Brennan
Brennan Associates


Contact Us